A 220 mm level change, a redesigned staircase

A change of roughly 220 mm in the ceiling level made the intended S-shaped staircase unsuitable. We recognised and explained this before fabrication, and developed revised options.

  • ProjectPrivate house
  • ScopeBespoke staircase, redesign and coordination
  • StageDesign change part-way through the project

The situation

Bespoke staircase works where the building design evolved around the staircase, so redesign and coordination were needed part-way through the project.

What we identified

A ceiling and structural level change of approximately 220 mm meant the planned S-shaped arrangement no longer gave suitable clearance under Approved Document K. Continuing with the original design would have produced a stair that did not work, either for compliance or in daily use.

What we did

We explained the geometric and buildability implications to the project team, then developed revised L-shaped and curved proposals with the wider construction team and the responsible designers, subject to formal design approval at each step.

What this demonstrates

Recognising when an architectural change invalidates a staircase solution, explaining the consequence before anyone is committed to fabrication, and developing practical alternatives while respecting the roles of the appointed designers.

Client and project details are kept confidential. Measurements and records are held on our project files.

More cases

← Back to WSMU Consulting

Facing something similar?

If you are looking at a staircase, guarding or buildability problem, or want a second pair of eyes before work is committed, the first conversation is free and without obligation.

Start with a conversation

Tell us what you are dealing with. If we can help, you will receive a written scope and fee proposal before any chargeable work begins.

Send an enquiry